Item(s) you searched for "0055120"

Products Found (5)



More Results (10)

Walraven WHA1 Highload Anchors

...and Benefits: ETA Option 1 approval for cracked and non-cracked concrete Seismic performance categories C1 and C2 for design of anchorages under seismic action Fire resistance class R30-R120 for design of anchorages under exposure to fire Very high...

Read more

Walraven WTB1 & WTB7 Throughbolt Anchors

...ETA Option 1 approval for cracked and non-cracked concrete Innovative zinc-flake corrosion-resistant coating Two embedment depths for maximum installation flexibility Fire resistance class R30-R120 for design of anchorages under exposure to fire... Walraven WTB1 SSt Through bolt Anchors ETA Option 1 approval for cracked and non-cracked concrete Made of stainless steel for maximum corrosion resistance Two embedment depths for maximum installation flexibility Fire resistance class R30-R120 for...

Read more

Walraven WCA1 Ceiling Anchors

...and Benefits: ETA ETAG001 Part 6 approval for multiple uses for non-structural applications Simple and quick installation procedure Correct anchor installation can be verified by simple visual check Fire resistance class R30-R120 for design...

Read more

How to choose suitable vibration isolators for outside AC splits?

...,0 18,6% 78,7% 87,4% 91,6% 94,8% 97,1% 98,2% 150 15 12,0 57,3% 86,8% 91,9% 94,5% 96,6% 98,1% 98,8% 2800200250 200 20 9,6 40,3% 82,9% 89,7% 93,1% 95,7% 97,6% 98,5% 250 25 12,0 57,3% 86,8% 91,9% 94,5% 96,6% 98,1% 98,8% 2800200500 350 35 8,4 25,4... frequency Article no.: load on vibroisolator deflection RPM 500 800 1000 1200 1500 2000 2500 [N] [~kg] [mm] Hz 8,3 13,3 16,7 20,0 25,0 33,3 41,7 2800300050 25 2,5 11,5 54,6% 86,1% 91,5% 94,3% 96,4% 98,0% 98,7% 50 5 23,0 81,5% 93,5% 95,9% >97,2...

Read more

How to choose suitable vibration isolators for industrial processing?

...% 98,1% 98,8% 2800200500 350 35 8,4 25,4% 80,0% 88,0% 92,0% 95,0% 97,3% 98,3% 500 50 12,0 57,3% 86,8% 91,9% 94,5% 96,6% 98,1% 98,8% 2800200750 550 55 8,8 31,1% 81,0% 88,6% 92,4% 95,3% 97,4% 98,3% 600 60 9,6 40,3% 82,9% 89,7% 93,1% 95,7% 97,6...® MS-1 Damping efficiency upon disturbing frequency Article no.: load on vibroisolator deflection RPM 500 800 1000 1200 1500 2000 2500 [N] [~kg] [mm] Hz 8,3 13,3 16,7 20,0 25,0 33,3 41,7 2800300050 25 2,5 11,5 54,6% 86,1% 91,5% 94,3% 96,4% 98,0% 98,7...

Read more

How to choose suitable vibration isolators for rooftop chillers, refrigeration and air handling units?

...100 10 8,0 18,6% 78,7% 87,4% 91,6% 94,8% 97,1% 98,2% 150 15 12,0 57,3% 86,8% 91,9% 94,5% 96,6% 98,1% 98,8% 2800200250 200 20 9,6 40,3% 82,9% 89,7% 93,1% 95,7% 97,6% 98,5% 250 25 12,0 57,3% 86,8% 91,9% 94,5% 96,6% 98,1% 98,8% 2800200500... disturbing frequency Article no.: load on vibroisolator deflection RPM 500 800 1000 1200 1500 2000 2500 [N] [~kg] [mm] Hz 8,3 13,3 16,7 20,0 25,0 33,3 41,7 2800300050 25 2,5 11,5 54,6% 86,1% 91,5% 94,3% 96,4% 98,0% 98,7% 50 5 23,0 81,5% 93,5...

Read more

Walraven WDI1 Drop-in Anchors

...concrete members and precast prestressed hollow core concrete slabs. Features and benefits: ETA ETAG001 Part 6 approval for multiple use for non-structural applications Fire resistance class R30-R120 for design of anchorages under exposure to fire Simple...

Read more

Walraven WCS1 Concrete Screws

...in up to 3 anchoring depths for maximum design flexibility Reduced edge and anchor spacing distances Fire resistance class R30-R120 for design of anchorages under exposure to fire Information request Do you need information about Walraven W-LX Concrete Screws? Fill in our form and we will be in touch. Approved |  Also suitable for...

Read more

How to choose suitable vibration isolators for backup power generators and cogeneration plants?

...VibraTek® MS-1 Walraven VibraTek® MS-1 Damping efficiency upon disturbing frequency Article no.: load on vibroisolator deflection RPM 500 800 1000 1200 1500 2000 2500 [N] [~kg] [mm] Hz 8,3 13,3 16,7 20,0 25,0 33,3 41,7 2800300050 25 2,5 11,5... VibraTek® MS-4 Walraven VibraTek® MS-4 Damping efficiency upon disturbing frequency Article no.: load on vibroisolator deflection RPM 500 800 1000 1200 1500 2000 2500 [N] [~kg] [mm] Hz 8,3 13,3 16,7 20,0 25,0 33,3 41,7 2800501000 800 80 18,4...

Read more

How to choose suitable vibration isolators for inline fans and equipment?

...Walraven VibraTek® HS-1 Walraven VibraTek® HS-1 Damping efficiency upon disturbing frequency Article no.: load on vibroisolator deflection RPM 500 800 1000 1200 1500 2000 2500 [N] [~kg] [mm] Hz 8,3 13,3 16,7 20,0 25,0 33,3 41,7 2800600050 25 2... 20 18,4 75,8% 91,7% 94,9% 96,5% 97,8% 98,8% 99,2% 250 25 23,0 81,5% 93,5% 95,9% 97,2% 98,2% 99,0% 99,4% 2800600500 300 30 13,8 64,8% 88,7% 93,0% 95,3% 97,0% 98,3% 98,9% 400 40 18,4 75,8% 91,7% 94,9% 96,5% 97,8% 98,8% 99,2% 500 50 23,0 81,5...

Read more

Let's get in touch

Product wish list 0
To top
Close

Asia